        Vertical Shaft Wall
        Horizontal Shaft Wall

        Enlarge

        USG Wall Shaft Systems are engineered to withstand pressure loads and provide in-service impact resistance to ensure long-term performance and durability. Use this section to determine the wall assembly to use and the size and gauge of framing. You will need to know elevator pressures and other in-service demands, and can use an elevator pressure table.

        USG Shaft Wall Systems are non-load bearing  gypsum wall partition assemblies constructed from outside the shaft at each floor. The assemblies are constructed of gypsum liner panels friction fitted to studs in a progressive manner, with gypsum panels, gypsum fiber panels or cement board applied to the face.

        USG Shaft Wall Systems installed horizontally provide economical construction for fire-resistive duct enclosures, corridors ceilings and stairway soffits.

        双色球公式计算推红球

        双色球公式计算推红球

        Ceiling Membrane of 1-Hour Corridor
        Ceiling Membrane of 1-Hour Corridor

                                                                                                                                                                                

        Stud Steel Member Designation Limiting Span
        212CH25-18 8' 6"
        400CH25-18 9' 3"
        212CH20-34 10' 4"
        400CH20-34 14' 11"
        600CH20-34 20' 10"

        双色球公式计算推红球

        Assembly with Double-Layer 1/2" or 5/8" Gypsum Panels

        Ceiling Membrane of 2-Hour Corridor
        Ceiling Membrane of 2-Hour Corridor

                                                                                                                                                                                           

        Stud Steel Member Designation Limiting Span
        212CH20-34 7' 7"
        212CH25-18 7' 10"
        400CH25-18 9' 8"
        400CH20-34 14' 0"
        600CH20-34 19' 7"

        双色球公式计算推红球

        Assembly with Triple-Layer 1/2" Gypsum Panels

        2-Hour Rated Assembly - Horizontal Membrane or Duct Enclosure
        2-Hour Rated Assembly - Horizontal Membrane or Duct Enclosure

                                                                                                                                                                                             

        Limiting Span

        The Horizontal Duct Enclosure System is limited to a span of 5' 4" long.

        Note: For larger spans, please refer to UL Designs I506, K504 and K506.

      3. <u id="e41878" ><code id="e41878" ></code></u>

        <listing id="e41878" ></listing>

      4. <listing id="e41878" ><td id="e41878" ></td></listing>

          <p id="e41878" ></p>

          <blockquote id="e41878" ></blockquote>

          1. <bdo id="e41878" ></bdo><s id="e41878" ><rp id="e41878" ><button id="e41878" ></button></rp></s>
          2. <strike id="e41878" ><optgroup id="e41878" ></optgroup></strike>